Lead4pass HPE0-S60 Dumps Actual Exam Material Updated Jan 2023

Looking forward to passing the HP HPE0-S60 exam? We at Lead4pass provide you with the latest and most accurate HPE0-S60 dumps actual exam material to help you prepare for the Delta – HPE Compute Solutions exam.

Lead4pass provides the latest exam questions for the HP HPE0-S60 exam. Lead4pass HPE0-S60 dumps https://www.leads4pass.com/hpe0-s60.html with PDF and VCE, real HPE0-S60 exam material exam questions and answers 79+, 100% high quality and accuracy. Pass the exam with ease.

New Updated HPE0-S60 Exam Material 2023 Free 

Total number of free questionsFromLatest update
15Lead4pass HPE0-S60 dumps2023

Questions and answers from HPE0-S60 free dumps are 100% free and guaranteed. 

Question 1:

Which compute node parameters are captured within the server hardware type?

A. Number of the CPUs

B. installed operating system

C. Mezzanine card configuration

D. Size of the memory Installed

 

Correct Answer: B


Question 2:

 

Which statement about manual orchestration during the firmware update is true?

A. It is supported only for logical enclosures with at least three frames

B. It provides an ability to select and update one side of the Interconnect topology at a time

C. It provides the ability to install an older firmware version than currently Installed In the interconnect

D. It allows all the interconnect modules to be activated manually at the same time.

 

Correct Answer: B


Question 3:

 

Which statement about the HPE D3940 storage module is true?

A. SATA drives require redundant 10 adapters to be installed in this module

B. Up to five modules can be installed in a single frame with Gen10 servers

C. it is configured through CLl available from the HPE Synergy console

D. Only one type of drive (SATA, SAS, SSD) can be installed in each module

 

Correct Answer: C


Question 4:

 

Your customer has 6 logical enclosures spanning 18 HPE Synergy frames. The customer needs to add one more logical enclosure based on 5 HPE Synergy frames.

How will this change impact the customer environment?

A. The customer can add a new logical enclosure to the existing setup because the maximum number of logical enclosures in a single management ring is not reached.

B. The customer has to expand the management ring capacity either by adding HPE Composer 2 modules or adding memory to reach 128GB per module.

C. The customer has to create a new management ring for a new logical enclosure because the maximum number of frames m a single management ring is reached.

D. The customer can add a new logical enclosure to an existing setup once all required licenses are added to HPE OneView and associated with the new frames.

 

Correct Answer: A

 


Question 5:

 

Your customer plans to deploy VMware vSAN using D3940 Storage Modules. Which statement about this solution is true?

A. The 12Gb SAS modules required for D3940 connectivity can only be installed in the first fabric.

B. To use the storage controller that will access D3940 storage modules, a second CPU must be installed.

C. For VMware vSAN deployment, all drives in the D3940 storage modules must be SSD drives.

D. All drives in the D3940 storage modules must formulate a single logical drive with RAID5 configured

 

Correct Answer: A


Question 6:

 

Your customer wants to add dedicated Fibre Channel connectivity to the HPE Synergy frame running HPE Synergy 480 Gen10 compute modules, each with one CPU socket populated Currently they use two 12 Gb SAS switches and two HPE Virtual Connect SE 100Gb F32 Modules for HPE Synergy installed in third fabric.

What must be done to enable dedicated FC connectivity for this HPE Synergy frame?

A. A second CPU must be installed for all HPE Synergy 480 Gen10 compute nodes.

B. For Brocade switches, a logical interconnect group must be created in HPE OneView.

C. For VC-FC modules, all server-facing ports must be properly licensed.

D. SAS switches must be moved to the second fabric and FC modules Installed in the first one.

 

Correct Answer: D


Question 7:

 

Your customer plans to expand an existing nPar based on a single HPE Superdome Flex chassis. Which statement about workload availability during expansion is true?

A. Powered nPar can be expanded only if HPE Superdome Flex 280 is used

B. Online expansion is available only if RMC is used for management.

C. HPE Superdome Flex does not support the expansion of powered-on nears

D. Powered nPar can be expanded if it does not use HPE Persistent Memory

 

Correct Answer: A


Question 8:

 

Which tool can be used to evaluate me health of an HPE Oneview appliance before proceeding with an appliance update?

A. HPE Composer Maintenance Console

B. HPE OneView Update Readiness Checker

C. HPE OneView Global Dashboard

D. HPE OneView Firmware Compliance Report

 

Correct Answer: A

 


Question 9:

 

A logical interconnect group can span multiple HPE Synergy frames for which interconnect type?

A. Brocade 32GB Fibre Channel Switch Module for HPE Synergy

B. HPE Virtual Connect SE 32 Gb FC Module for Synergy

C. HPE Virtual Connect SE 100 Gb F32 Module tor Synergy

D. HPE Synergy 12 Gb SAS Connection Module

 

Correct Answer: C


Question 10:

 

Your customer manages HPE Synergy using HPE OneView. For one of its projects, the company purchased 50 HPE.

ProLiant DK385 Gen10 Plus v2. They plan to manage the new systems using HPE OneView as well.

What should the customer do to manage the rack system using HPE OneView?

A. add the rack system to the HPE OneView instance used to manage HPE Synergy to centralize the management of all systems.

B. connect the rack system to an IPDU and add the IPDU to the HPE. OneView instance that is used for HPE synergy management.

C. Deploy HPE OneView Global Dashboard and add the rack systems there, as AMD systems are not directly in HPE OneView.

D. Deploy an HPE OneView virtual appliance, and, after configuration, use it to manage only the rack systems.

 

Correct Answer: D


Question 11:

 

Which statement about a new HPE SimpliVity deployment is true?

A. New HPE SimpliVity deployments give customer flexible choice of hypervisor

B. A new HPE SimpliVity node can be a member of multiple dusters

C. AM new HPE SimpliVity models are software optimized

D. All new HPE SimpliVity models are based on mid CPUs

 

Correct Answer: A


Question 12:

 

You plan to configure a Link Aggregation Group (LAG) for two connections within a server profile for a compute node running an ESXI system.

What is required from the VMware side to enable LAG?

A. Virtual Distributed Switch

B. vSphere Standard license

C. Load balancing cluster

D. Dedicated VMKernel port

 

Correct Answer: D


Question 13:

 

In the past, a customer experienced a networking issue where network ports went down and came back up in quick succession.

Which HPE Virtual Connect SE 100 GD F32 Module for the HPE Synergy feature can be configured to disable such ports?

A. Pause flood protection

B. sFlow

C. Storm control

D. Port flap protection

 

Correct Answer: B


Question 14:

 

Your customer reports mat an external FC boot volume for the Windows server is visible four times in Disk Management 1 online and 3 offline.

What should you do to resolve this issue?

A. Disable deduplication for this volume at the array level

B. Remove the offline disks using array management tools

C. Install and configure MPIO on my Windows system

D. Remove the offline disks using Windows Disk Management

 

Correct Answer: C


Question 15:

 

Your customer plans to use HPE Primera to boot HPE Synergy compute nodes. They currently have two HPE Virtual Connect SE 100Gb F32 Module for Synergy modules installed in the frame. The customer wants to use FC as a storage access protocol.

What must be done to complete this task?

A. Enable FC primary and secondary boot on the modules through the HPE OneView interface

B. FC connectivity on the modules should be enabled through the service console by disabling FCoE.

C. Add FC upgrade licenses in HPE OneView that will enable FC connectivity for the modules

D. Enter both modules into a maintenance mode, then enable FC connectivity through CLI

 

Correct Answer: B

 


 

See our full HPE0-S60 dumps if you want to get a further understanding of the materials.

Finally,

To pass the HPE0-S60 exam easily, all you need to do is get the updated Lead4pass HPE0-S60 dumps exam materials https://www.leads4pass.com/hpe0-s60.html with PDF and VCE (HPE0-S60 exam questions) for the amazing Delta – HPE Compute Solutions exam.

Previous post Lead4Pass HPE6-A67 Exam Dumps | Valid Exam Material – January 2023
Next post Lead4pass HPE6-A73 Dumps Latest Learning Materials Updated 2023-01