Lead4pass HPE0-V14 Dumps Actual Exam Material Updated July 2022
Looking forward to passing the HP HPE0-V14 exam? We at leads4pass provide you with the latest and most accurate HPE0-V14 dumps actual exam material to help you prepare for the Building HPE Hybrid IT Solutions exam.
leads4pass provides the latest exam questions for the HP HPE0-V14 exam. leads4pass HPE0-V14 dumps https://www.leads4pass.com/hpe0-v14.html with PDF and VCE, real HPE0-V14 exam material exam questions and Answers 301+, 100% high quality and accuracy. Pass the exam with ease.
Actual Exam Material Share Free HPE0-V14 Exam Questions
Total number of free questions | From | Latest update |
15 | leads4pass HPE0-V14 dumps | 2022 |
Questions and answers from HPE0-V14 free dumps.
Question 1:
Which HPE solution brings together CPU, Memory, and Disk with an unpredictable workload into a single management infrastructure?
A. dHCI
B. SimpliVity
C. Nimble
D. Primera
Correct Answer: B
Reference: https://community.hpe.com/t5/Around-the-Storage-Block/Accelerating-hyperconvergence-with-end-to-end-25GbE-storage/ba-p/7001560
Question 2:
Read the question, and then refer to the exhibit.
display interface Ten-GigabitEthernet 1/0/1 Ten-GigabitEthernet1/0/1 Current state: Administratively DOWN Line protocol state: DOWN IP packet frame type: Ethernet II, hardware address: d894-03fb-793d Description: TenGigabitEthernet1/0/1 Interface Bandwidth: 10000000 kbps Loopback is not set Media type is stack wire, port hardware type is STACK_SFP_PLUS Unknown-speed mode, unknown-duplex mode Link speed type is autonegotiation, link duplex type is autonegotiation Flow-control is not enabled Maximum frame length: 10000 Allow jumbo frames to pass Broadcast max-ratio: 100% Multicast max-ratio: 100% Unicast max-ratio: 100% PVID: 1 MDI type: Automdix Port link-type: Trunk VLAN Passing: 10, 20 VLAN permitted: 10, 20 Trunk port encapsulation: IEEE 802.1q Port priority: 0 Last link flapping: 0 hours 0 minutes 18 seconds Last clearing of counters: Never Peak input rate: 78 bytes/sec, at 2011-03-31 04:55:57 Peak output rate: 15 bytes/sec, at 2011-03-30 23:00:57 Last 300 second input: 0 packets/sec 67 bytes/sec -% Last 300 second output: 0 packets/sec 14 bytes/sec -% Input (total): 62670 packets, 8565340 bytes 0 unicasts, 0 broadcasts, 62670 multicasts, 0 pauses Input (normal): 62670 packets, -bytes 0 unicasts, 0 broadcasts, 62670 multicasts, 0 pauses Input: 0 input errors, 0 runts, 0 giants, 0 throttles 0 CRC, 0 frame, -overruns, 0 aborts ?ignored, -parity errors Output (total): 3707 packets, 1294835 bytes 0 unicasts, 0 broadcasts, 3707 multicasts, 0 pauses Output (normal): 3707 packets, -bytes 0 unicasts, 0 broadcasts, 3707 multicasts, 0 pauses Output: 0 output errors, -underruns, -buffer failures 0 aborts, 0 deferred, 0 collisions, 0 late collisions 0 lost carrier, -no carrier
A customer added a new switch to their network. They connected it using the interface Ten-GigabitEthernet 1/0/1. They are using VLAN 10 and 20 for the devices in their network.
The new switch was fully operational. Then, the customer experienced a power failure later that day and could not reach any device on the new switch after the power returned.
From the output in the exhibit, would this be the issue?
A. The interface loopback is not set.
B. The interface link speed and duplex are unknown.
C. The interface is administratively down.
D. The interface is configured for a PVID of VLAN 1.
Correct Answer: C
“display interface Ten-GigabitEthernet 1/0/1 Ten-GigabitEthernet1/0/1 Current state: Administratively DOWN Line protocol state: DOWN IP”
Question 3:
A customer needs to deploy an application on a newly-installed HPE ProLiant server, but they report that the server is not online. They call you for remote support. The IP address on the production network cannot be reached. You are evaluating the probable root causes of this issue.
According to the troubleshooting methodology, what are the next two steps? (Select two)
A. Remote console into the ToR switch to check the server\’s port configuration.
B. Log in to iLO to see if the server hardware and NIC are online and configured correctly.
C. Use OneView to see f the server firmware is up-to-date
D. Run insight Diagnostics on the Server
E. Use Microsoft Remote Desktop or VNC to check the server\’s NIC and IP address configuration
Correct Answer: BD
Question 4:
A customer needs a server memory subsystem that meets the following requirements:
1.
approaches the speed of traditional DRAM
2.
ensures high capacity, high performance, and ongoing data safety in case of a power failure
Which HPE memory feature meets the customer’s needs?
A. Load-Reduced DIMMs
B. Memory Mirroring
C. Fast Fault Tolerance Memory
D. Persistent Memory
Correct Answer: D
Reference: https://www.hpe.com/emea_europe/en/servers/persistent-memory.html
Question 5:
A customer needs to integrate a new digital video surveillance solution into their existing environment and available network ports. The solution needs to include redundant hypervisor servers and a redundant SAN with a shared Fibre Channel attached storage array.
You plan to propose the following configuration:
2 HPE DL380 Gen10 servers with dual processors, 384 GB of memory, dual-port 10 Gb NIC, and High-Performance Fan Kit 1 HPE MSA 2050 Dual Controller Storage Array with 24x 1.8 TB 10 K SAS drives and 96x 7.2K NL drives 4 VMware vSphere Standard licenses 1 VMware vCenter Server Foundation licenses 5 years 24x7x4 support for all equipment
What must be added to the configuration to provide a complete solution? (Choose two.)
A. 2 HPE 10/25 Gb 2-port 622FLR-SFP28 CNA
B. 2 HPE FlexFabric 5710 switches
C. 2 Aruba 8320 switches
D. 2 HPE SN3000B switches
E. 2 HPE StoreFabric SN1200E 16 Gb Dual Port FC HBAs
Correct Answer: DE
Question 6:
Refer to the exhibit.
You are asked to review a server configuration for a customer before it is quoted. The server will be used in a business-critical environment and high availability is required. The server configuration is shown in the exhibit.
What should be added to the configuration to ensure availability?
A. HPE Smart Array P408i-a SR Gen10 12 G SAS Modular Controller
B. HPE DL380 Gen10 Intel Xeon-Gold 6143 (2.8 GHz/16-core/205 W) Processor Kit
C. HPE 800W Flex Slot Platinum Hot Plug Low Halogen Power Supply Kit
D. HPE DL38X Gen10 12 Gb SAS Expander Card Kit
Correct Answer: C
Question 7:
Which HPE feature enables the customer to achieve this A customer has a new virtual environment. They selected HPE servers for the environment in order to achieve better performance for their applications. server performance improvement?
A. embedded application
B. workload performance advisor
C. workload profile
D. Active Health System
Correct Answer: C
Question 8:
Which feature in a block storage array eliminates redundant data through the process of using indexes that refer to the original set of data?
A. deduplication
B. compression
C. thin provisioning
D. thick provisioning
Correct Answer: A
Reference: https://searchstorage.techtarget.com/definition/data-deduplication
Question 9:
Why is SNMPv2c considered to be insecure?
A. SNMPv2c agents only accept GET requests which match their read-only community string
B. SNMPv2c community strings are transmitted in clear text
C. SNMPv2c only allows the signing of the message payload
D. SNMPv2c agents only encrypt WRITE messages.
Correct Answer: B
Question 10:
A small, expanding law firm wants to replace its single Windows server
The server will be kept in their library without a rack. They want a server that allows for internal storage growth and is capable of adding PCI adapters.
Which HPE server model type should you recommend?
A. HPE BL
B. HPE XL
C. HPE DL
D. HPE ML
Correct Answer: D
Question 11:
A customer needs to update a server\’s firmware using the latest Support Pack for ProLiant (SPP). They use a bootable USB flash drive to do so, and they select Interactive Mode on boot. Once the device boots, they are unsure how to proceed and ask for your assistance.
What can you tell them to do to easily update the firmware?
A. Download a new version of Smart Update Manager.
B. From Interactive mode, select the “Force Firmware” option.
C. Reboot the server with the flash drive and leave in default mode.
D. Run interactive mode from the Operating System instead.
Correct Answer: B
Question 12:
Which network protocol is used to build a loop-free logical topology for Ethernet networks?
A. SCSP
B. ECP
C. VLAN
D. STP
Correct Answer: D
Question 13:
Which series of internal checks will an HPE ProLiant server use to validate that the base hardware components are working correctly before booting the operating system?
A. CMOS
B. EDO
C. POST
D. BIOS
Correct Answer: C
Question 14:
A solution integrator is installing new data center components including an HPE G2 Advanced Rack with two Standard Series G2 PDUs A customer observing the installation process questions whether there will be sufficient power for additional equipment that may be added in the future.
How should the solution integrator respond?
A. HPE G2 Advanced racks allow additional PDUs to be added if additional equipment requires more outlets or more available power
B. HPE Standard Series G2 PDUs allow additional inlet power cords to support additional equipment in the future.
C. HPE PDUs support elevated temperatures up to 75 (1673F), in case the additional equipment power draw results in increased heat generation.
D. Two HPE Standard G2 PDUs will support 42U of racked equipment, so any equipment added in the future will be accommodated by the current PDU configuration
Correct Answer: D
Question 15:
Which storage array feature records only changes made to the base volume and keeps an earlier state of the original volume?
A. snapshot
B. clone
C. virtual volume
D. volume mirror
Correct Answer: A
Reference: https://assets.ext.hpe.com/is/content/hpedam/a00093683enw (10)
Finally,
To pass the HPE0-V14 exam easily, all you need to do is get the updated leads4pass HPE0-V14 dumps exam materials https://www.leads4pass.com/hpe0-v14.html with PDF and VCE (HPE0-V14 exam questions) for the amazing Building HPE Hybrid IT Solutions exam.